Aviosys 9070 Manuel d'utilisateur Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
- 22-
Ref#92550806002
Some uses of this function would be for systems or computers that require a shut
down time
Delay after action (Seconds): The number of seconds it takes the attached
devices to startup. Once those devices start, the Startup Action will be activated
to continue pinging or stop pinging.
Continue Ping: After start up Delay has been reached the start up action will
either Continue Pinging or Stop Pinging
Action: When the number of Ping Failures have been reached. The device can
be set to perform a Off, On, or Reset function.
Ping Interval (Seconds): The number of seconds between each ping
Ping Echo Wait (Milliseconds): The number of milliseconds the device will wait
for a response from the pinged device if no ping is detected within this time it will
be considered a ping failure.
Please view the example below for more details:
In the picture above:
1.) Power 1 Ping function is enabled for two websites
2.) The 9258xx will ping the web address www.sample.com & www.google.com
3.) If there is a response within the Ping Echo Wait the 9258xx will send
another ping signal the set Ping Interval which is 3 seconds for this
example.
4.) If the 9258xx does not receive a response from the device it will constitute a
Ping Failures.
5.) After 3 consecutive failure the device will go to the Action Delay section. In
this case the device will delay for 3 seconds.
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 35 36

Commentaires sur ces manuels

Pas de commentaire